Total RNA Purification Kits
For research use only and NOT intended for in vitro diagnostics.
CE-IVDR marked diagnostic version available here
Total RNA Purification Kits
Register today to receive an exclusive 15% off* on your first order.
Supporting Data
Kit Specifications
|
|
Maximum Binding Capacity
|
Up to 50 μg RNA
|
Maximum Loading Volume
|
650 μL
|
Size of RNA Purified
|
All sizes, including small RNA (< 200 nt)
|
Maximum Amount of Starting Material
|
|
Animal Cells | 3 x 106 cells |
Animal Tissues | 10 mg (for most tissues*) |
Blood | 100 μL |
Plasma/Serum | 200 μL |
Bacteria | 1 x 109 cells |
Yeast |
1 x 108 cells
|
Fungi |
50 mg
|
Plant Tissues |
50 mg
|
Time to Complete 10 Purifications |
20 minutes
|
Average Yield | |
HeLa Cells (1 x 106 cells) | 15 μg |
E. coli (1 x 109 cells) | 50 μg |
* for isolating total RNA from larger amounts of tissue, please use Norgen's Animal Tissue RNA Purification Kit (Cat# 25700)
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. These kits are stable for 2 years after the date of shipment.
Component | Cat. 17200 (50 preps) | Cat. 37500 (100 preps) | Cat. 17250 (250 preps) | Cat. 17270 (500 preps) | Cat. 24300 (192 preps) | Cat. 24370 (576 preps) | Cat. 24350 (192 preps) | Cat. 24380 (576 preps) |
---|---|---|---|---|---|---|---|---|
Buffer RL | 40 mL | 2 x 40 mL | 175 mL | 350 mL | 2 x 40 mL | 350 mL | 2 x 40 mL | 350 mL |
Wash Solution A | 38 mL | 2 x 38 mL | 148 mL | 1 x 148 mL 1 x 74 mL |
2 x 38 mL | 1 x 74 mL 1 x 148 mL |
2 x 38 mL | 1 x 74 mL 1 x 148 mL |
Elution Solution A | 6 mL | 2 x 6 mL | 30 mL | 60 mL | 2 x 20 mL | 60 mL | 2 x 20 mL | 60 mL |
Mini Spin Columns | 50 | 100 | 250 | 500 | - | - | - | - |
96-Well Isolation Plate | - | - | - | - | 2 | 6 | - | - |
96-Well Isolation Plate (Deep Well) | - | - | - | - | - | - | 2 | 6 |
Adhesive Tape | - | - | - | - | 4 | 12 | 4 | 12 |
Collection Tubes | 50 | 100 | 250 | 500 | - | - | ||
96-Well Collection Plate | - | - | - | - | 2 | 6 | - | - |
96-Well Collection Plate (Deep Well) | - | - | - | - | - | - | 2 | 6 |
Elution Tubes (1.7 mL) | 50 | 100 | 250 | 500 | - | - | ||
96-Well Elution Plate | - | - | - | - | 2 | 6 | - | - |
96-Well Elution Plate (Deep Well) | - | - | - | - | - | - | 2 | 6 |
Product Insert | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Documentation
(37500) Total RNA Purification Kit (Spin Column) - Protocol (100 prep)
(17250) Total RNA Purification Kit (Spin Column) - Protocol (250 prep)
(17270) Total RNA Purification Kit (Spin Column) - Protocol (500 prep)
(24300) Total RNA Purification 96-Well Kit (High Throughput) - Protocol (96-well) - (2 x 96-well plates)
(24370) Total RNA Purification 96-Well Kit (High Throughput) - Protocol (96-well) - (6 x 96-well plates)
(24350) Total RNA Purification 96-Well Kit (High Throughput Deep Well) - Protocol (Deep Well) - (2 x 96-well plates)
(24380) Total RNA Purification 96-Well Kit (High Throughput Deep Well) - Protocol (Deep Well) - (6 x 96-well plates)
Total RNA Purification Kit - Supplementary Protocol for Exosomal RNA Purification from Exosomes Already Purified
Supplementary Protocol for Total RNA Isolation from Staphylococcus aureus-Related Bacteria and Hard-to-Lyse Bacterial Species
Isolation of RNA from Norgen’s Swab Collection and Total Nucleic Acid Preservation System
Supplementary Protocol - Norgen's Saliva RNA Collection and Preservation Devices
Supplementary Protocol for Isolating Viral RNA from Swab Samples
Isolation of True Total RNA using the Tempus™ Blood RNA Tube and Norgen’s Total RNA Purification Kit
Effect of RNA Isolation Method on microRNA Quantity and Quality in Plasma: A Comparative Study
Revised Guidelines for RNA Quality Assessment for Diverse Biological Sample Input
Total RNA/DNA Purification and Detection from Blood Preserved on a Neoteryx™ Mitra Microsampling Device
Effect of microRNA GC Content on RNA Purification Efficiency
37500 - Total RNA Purification Kit (Spin Column 100 Prep) - SDS
17250 - Total RNA Purification Kit (Spin Column 250 Prep) - SDS
17270 - Total RNA Purification Kit (Spin Column 500 Prep) - SDS
24300 - Total RNA Purification Kit Dx (2x 96 Well Plates) - SDS
24350 - Total RNA Purification Kit Dx (2x 96 Deep Well Plates) - SDS
24370 - Total RNA Purification Kit Dx (6x 96 Well Plates) - SDS
24380 - Total RNA Purification Kit Dx (6x 96 Deep Well Plates) - SDS
Substrate Specificity of Taq Polymerase - ASCB 2007
Genomic Profiling of Hepatitis B Virus and Hepatitis C Virus From 1 mL of Urine - ASM 2007
Silicon Carbide As A Novel RNA Affinity Medium With Improved Sensitivity and Size Diversity - microRNA 2008
Effect of RNA Isolation Methods On microRNA Quantity and Quality In Plasma - TriCon 2013
Revised Guidelines For RNA Quality Assessment For Diverse Biological Sample Input - ASCB 2008
Variation Between The Purification Efficiency of microRNA With Different Gc Content - TriCon 2013
The Impact of Sample Preparation On Microrna Quality and Diversity For Downstream Applications - microRNA 2009
Rapid and qPCR ready DNA isolation from environmental and human bodily fluid samples using Magnetic bead system
Videos
Total RNA Purification Tutorial (Cat. 17200)
FAQs
Spin Column, High Throughput, High Throughput Deep Well
Poor RNA recovery could be due to one or more of the following:
- Incomplete lysis of cells or tissue. Ensure that the appropriate amount of Buffer RL was used for the amount of cells or tissue.
- Column has become clogged. Do not exceed the recommended amounts of starting materials. The amount of starting material may need to be decreased if the column shows clogging below the recommended levels. See FAQ related to “Clogged Columns/wells” below.
- An alternative elution solution was used. It is recommended that the Elution Solution A supplied with this kit be used for maximum RNA recovery.
- Ethanol was not added to the lysate. Ensure that the appropriate amount of ethanol is added to the lysate before binding to the column.
- Ethanol was not added to the Wash Solution A. Ensure that 90 mL of 96-100% ethanol is added to the supplied Wash Solution A prior to use.
- Low RNA content in cells or tissues used. Different tissues and cells have different RNA contents, and thus the expected yield of RNA will vary greatly from these different sources. Please check literature to determine the expected RNA content of your starting material.
- Cell Culture: Cell monolayer was not washed with PBS. Ensure that the cell monolayer is washed with the appropriate amount of PBS in order to remove residual media from cells.
- Yeast: Lyticase was not added to the Resuspension Buffer. Ensure that the appropriate amount of lyticase is added when making the Resuspension Buffer.
- Bacteria and Yeast: All traces of media not removed. Ensure that all media is removed prior to the addition of the Buffer RL through aspiration.
Column/well clogging can result from one or combination of the following factors:
- Insufficient solubilization of cells or tissues. Ensure that the appropriate amount of Buffer RL was used for the amount of cells or tissue.
- Maximum number of cells or amount of tissue exceeds kit specifications. Refer to specifications to determine if the amount of starting material falls within kit specifications.
- High amounts of genomic DNA present in sample. The lysate may be passed through a 25 gauge needle attached to a syringe 5-10 times in order to shear the genomic DNA prior to loading onto the column.
- Centrifuge temperature is too low. Ensure that the centrifuge remains at room temperature throughout the procedure. Temperatures below 15°C may cause precipitates to form that can cause the columns to clog.
RNA can be degraded due to the following factors:
- RNase contamination. RNases may be introduced during the use of the kit. Ensure proper procedures are followed when working with RNA. Please refer to “Working with RNA” at the beginning of this user guide.
- Procedure not performed quickly enough. In order to maintain the integrity of the RNA, it is important that the procedure be performed quickly. This is especially important for the Cell Lysate Preparation Step in the Animal Tissue protocol, since the RNA in animal tissues is not protected after harvesting until it is disrupted and homogenized.
- Improper storage of the purified RNA. For short term storage RNA samples may be stored at –20°C for a few days. It is recommended that samples be stored at –70°C for longer term storage.
- Frozen tissues or cell pellets were allowed to thaw prior to RNA isolation. Do not allow frozen tissues to thaw prior to grinding with the mortar and pestle in order to ensure that the integrity of the RNA is not compromised.
- Starting material may have a high RNase content. For starting materials with high RNase content, it is recommended that β-mercaptoethanol be added to the Buffer RL.
- Lysozyme or lyticase used may not be RNase-free. Ensure that the lysozyme and lyticase being used with this kit is RNase-free, in order to prevent possible problems with RNA degradation.
If the RNA does not perform well in downstream applications, it may be due to one or more of the following:
- RNA was not washed 3 times with the provided Wash Solution A. Traces of salt from the binding step may remain in the sample if the column is not washed 3 times with Wash Solution A. Salt may interfere with downstream applications, and thus must be washed from the column.
- Ethanol carryover. Ensure that the dry spin under the Column Wash Procedure is performed, in order to remove traces of ethanol prior to elution. Ethanol is known to interfere with many downstream applications.
The contamination with genomic DNA may be due to large amount of starting material used. Perform RNase-free DNase I digestion on the RNA sample after elution to remove genomic DNA contamination. It is recommended that Norgen’s RNase-Free DNase I Kit (Product # 25710) be used for this step.
Yes, the Total RNA purification kits can be used to purify RNA from samples like buffy coats and isolated PBMCs. For blood leukocyte samples, you can use a specialized product - Leukocyte RNA purification kit.
Yes, Total RNA purification kits can be used with samples stored in RNA protective agents like RNAlater. Norgen Biotek also provides a similar RNA preserve solution (Cat. 17260).
Yes, you can use Total RNA purification kits to purify RNA from insect samples. Please contact our Tech support team at support@norgenbiotek.com and ask for reference publications.
Yes, lysates prepared in buffer RL can be frozen at -80°C, and the remaining protocol can be performed at a later date.
Yes, you can use Norgen's Total RNA purification kits with the aqueous phase from samples prepared in TRIzol. Please contact our Tech Support team at support@norgenbiotek.com if you have any questions regarding the protocol.
Yes, Norgen Total RNA purification kits are compatible with tissue samples stored in OCT compound. Please contact our Tech Support team at support@norgenbiotek.com and ask for reference publications.