Soil DNA Isolation Plus Kit
For the detection of microorganisms from soil samples
For research use only and NOT intended for in vitro diagnostics.
Soil DNA Isolation Plus Kit
For the detection of microorganisms from soil samples
Register today to receive an exclusive 15% off* on your first order.
Features and Benefits
- Rapid and convenient method to detect microorganisms in soil samples
- Process all soil types
- Remove organic substances using the OSR Solution
- Remove all humic acid from DNA samples
- Fast and easy processing using a rapid spin-column format
- Isolate high quality total DNA from a variety of microorganisms including bacteria, fungi and algae
Norgen's Soil DNA Isolation Plus Kit provides a convenient and rapid method for the detection of microorganisms from soil samples. All types of soil samples can be processed with this kit, including common soil samples and difficult soil samples with high humic acid content such as compost and manure. The kit removes all traces of humic acid and PCR inhibitors using the provided the OSR (Organic Substance Removal) Solution. A simple and rapid spin column procedure is then used to further purify the DNA. Total genomic DNA can be isolated and purified from all the various microorganisms found in soil, such as bacteria, fungi and algae. The purified DNA is of the highest quality and is fully compatible with downstream PCR applications, as all humic acid substances and PCR inhibitors are removed during the isolation.
Details
Supporting Data
Kit Specifications
|
|
Maximum Soil Input |
250 mg
|
Type of Soil Processed |
All soil types
|
Maximum Column Binding Capacity |
50 μg
|
Maximum Column Loading Volume |
650 μL
|
Time to Complete 10 Purifications |
30 minutes
|
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year from the date of shipment.
Component | Cat. 64000 (50 preps) |
---|---|
Lysis Buffer D | 45 mL |
Lysis Additive A | 2 x 6 mL |
Binding Buffer I | 7 mL |
OSR Solution | 3 mL |
Lysis Buffer QP | 25 mL |
Wash Solution A | 18 mL |
Elution Buffer B | 8 mL |
Bead B Tubes | 50 |
Spin Columns | 50 |
Collection Tubes | 50 |
Elution Tubes (1.7 mL) | 50 |
Product Insert | 1 |
Documentation
Norgen’s Soil DNA Isolation Kit Outperforms a Competitor with Effective Humic Acid Removal for Metagenomic Studies
Norgen’s Improved Soil DNA Isolation Plus Kit Produces Yields and Quality Comparable With a Top Competitor
FAQs
Plus
Poor DNA recovery could be due to one or more of the following:
- Homogenization was incomplete.
Depending on the type of soil, further vortexing with the flat bed vortex or bead beater equipment may be required. However, it is not recommended to increase the vortex time to longer than 10 minutes at maximum speed.
- Lysis Additive A was not added to the lysate.
Ensure that the provided Lysis Additive A is added to separate humic acid and increase DNA yield.
- Lysis Buffer QP and Ethanol were not added to the lysate.
Ensure that 400 µL of Lysis Buffer QP and 550 µL of 96-100% ethanol are added to the lysate before binding to the column.
- Ethanol was not added to the Wash Solution A.
Ensure that 42 mL of 96-100% ethanol is added to the supplied Wash Solution A prior to use.
If the DNA does not perform well in downstream applications, it may be due to one or more of the following:
- Eluted DNA sample is brown.
The elution contains high humic acids. Ensure that the OSR Solution was added to the clean lysate. Also, ensure the column was washed with Binding Buffer B.
- DNA was not washed with the provided Binding Buffer B and Wash Solution A.
Traces of humic acids or salt from the binding step may remain in the sample if the column is not washed with the provided Binding Buffer B and Wash Solution A. Humic acids and salt may interfere with downstream applications, and thus must be washed from the column.
- Ethanol carryover.
Ensure that the dry spin under the Column Wash procedure is performed in order to remove traces of ethanol prior to elution. Ethanol is known to interfere with many downstream applications.
- PCR reaction conditions need to be optimized.
Take steps to optimize the PCR conditions being used, including varying the amount of template (10 ng to 50 ng for 20 µL of PCR reaction is recommended), changing the source of Taq polymerase, looking into the primer design, and adjusting the annealing conditions.
Citations
Title | Microbial Diversity Impacts Non-Protein Amino Acid Production in Cyanobacterial Bloom Cultures Collected from Lake Winnipeg |
Citation | Toxins 2023. |
Authors | Stephanie L. Bishop 1,2,*,†ORCID,Julia T. Solonenka 1,†,Ryland T. Giebelhaus 1,3,4ORCID,David T. R. Bakker 1,Isaac T. S. Li 1ORCID andSusan J. Murch 1ORCID |
Title | Molecular identification of Acanthamoeba spp., Balamuthia mandrillaris and Naegleria fowleri in soil samples using quantitative real-time PCR assay in Turkey; Hidden danger in the soil! |
Citation | Acta Tropica 2023. |
Authors | Mehmet Aykur a b, Hande Dagci b |
Title | Startup performance and microbial communities of a decentralized anaerobic digestion of food waste |
Citation | Chemosphere 2023. |
Authors | Yong Wei Tiong, Pooja Sharma, Hailin Tian, To-Hung Tsui, Heng Thong Lam, Yen Wah Tong, |
Title | Systematic screening of carbon-based anode materials for bioelectrochemical systems |
Citation | Journal of Chemical Technology & Biotechnology 2023. |
Authors | Zainab Ul, Pilar Sánchez-Peña, Mireia Baeza, Mira Sulonen, David Gabriel, Juan Antonio Baeza, Albert Guisasola |
Title | Utilizing novel Escherichia coli-specific conserved signature proteins for enhanced monitoring of recreational water quality |
Citation | MicrobiologyOpen 2023. |
Authors | Faizan Saleem, 1 Enze Li, 1 Kevin L. Tran, 1 Bashudev Rudra, 2 Thomas A. Edge, 1 Herb E. Schellhorn,corresponding author 1 and Radhey S. Guptacorresponding author 2 |